APV solar charger is a combination of APC inverter and solar charger. The APV pure sine wave inverter not only makes your solar system simple in wiring, but also has all the unique features from the inverter and solar charger.
Features of APV Pure Sine Wave Inverter, Solar Charger1. APV pure sine wave inverter adopts low quiescent current, and power saver mode to reduce power consumption to 10W(3s sensing cycle)/3W(30s sensing cycle) *. It can extract max. power from various batteries with different protections.2. High overload ability of our APV charger is up to 300% rated power(20 sec.), and low voltage trip 10.5V/11V or 10V/10.5V is selectable.3. Our APV solar charger can achieve reverse current protection and battery temperature compensation, with the high efficiency MPPT function(97%). Auto input DC voltage can be detected between 12V/24V.4. Our APV pure sine wave inverter supports 3-step intelligent battery charging, and equips with 8 preset battery type selector for totally flat batteries. Its powerful charge rate up to 90Amp**. In addition, PFC(power factor correction) is adopted for charger, which has less power consumption than conventional units5. LCD status display, USB communication port, battery/AC priority switch are available for our APV pure sine wave inverter, it also has 17 alarms/warnings for easier operation and trouble-shooting, and ability to switch the unit on/off. In addition, select/deselect power saver mode can be used too.Note:*For 1KW one. **For some models.6. The APV solar charger has 15s delay before transfer when AC resumes, and the function of overload protection when it equips with generator. Also, it allows start up and through power with depleted batteries.7. 10ms typical transfer time between battery and AC, which guarantees power continuity of APV pure sine wave inverter. Its input AC voltage is selectable (184-253V or 154-253V) for different kinds of loads.
Technical Parameters of APV Pure Sine Wave Inverter, Solar Charger
Electrical Specifications | |||||||
Model | APV 1000W | APV 2000W | APV 3000W | APV 4000W | APV 5000W | APV 6000W | |
Output (Inverter Mode) | Continuous Output Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W |
Surge Rating | 3000W | 6000W | 9000W | 12000W | 15000W | 18000W | |
Output Waveform | Pure sine wave/same as input(bypass mode) | ||||||
Nominal Efficiency | >88%(peak) | ||||||
Line Mode Efficiency | >95% | ||||||
Power Factor | 0.9-1.0 | ||||||
Nominal OutputVoltage rms | 120/230VAC | ||||||
Output Voltage Regulation | ±10% rms | ||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||||||
Short Circuit Protection | Yes( 10s after fault ) | ||||||
Typical Line Stansfer Time | 10ms(max.) | ||||||
THD | <3% | ||||||
DC Input | Nominal Input Voltage | 12V | 24V | 48V | |||
Minimum Start Voltage | 10V | 20V | 40V | ||||
Low Battery Alarm | 10.5V | 21V | 42V | ||||
Low Battery Trip | 10V | 20V | 40V | ||||
High Voltage Alarm | 16V | 32V | 64V | ||||
Low Battery Voltage Recover | 13V | 26V | 52V | ||||
Idle Consumption-Search Mode | < 25W when power saver on | ||||||
AC Charger | Input Voltage Range | 95-127VAC | 194-243VAC | 164-243VAC(W) | |||
Output Voltage | Depends on battery type | ||||||
Max Charge Rate | 35A / 70A | ||||||
Battery Initial Voltage for Start Up | 0-15.7V for 12V( *2 for 24V, *4 for 48V) | ||||||
Over Charge Protection Shutdown | 15.7V for 12V (*2 for 24V, *4 for 48V) | ||||||
Charger curve(4 stage constant current), battery types 4 step digital controlled progressive charge | |||||||
Battery type | Fast V, float V ( *2 for 24v, *4 for 48v) | ||||||
Gel U.S.A | 14 | 13.7 | |||||
A.G.M 1 | 14.1 | 13.4 | |||||
A.G.M 2 | 14.6 | 13.7 | |||||
Sealed Lead Acid | 14.4 | 13.6 | |||||
Gel Euro | 14.4 | 13.8 | |||||
Open Lead Acid | 14.8 | 13.3 | |||||
Calcium | 15.1 | 13.6 | |||||
De-sulphation | 15.5 for 4hrs | ||||||
Remote Control | Yes. Optional | ||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (grid or generator) | |||||
Nominal Voltage | 120VAC | 230VAC | |||||
Low Voltage Trip | 90V±4% | 184V/154V±4% | |||||
Low Voltage Re-engage | 100V±4% | 194V/164V±4% | |||||
High Voltage Trip | 140V±4% | 253V±4% | |||||
High Voltage Re-engage | 135V±4% | 243V±4% | |||||
Max. Input AC Voltage | 150VAC | 270VAC | |||||
Nominal Input Frequency | 50Hz or 60Hz (auto detect) | ||||||
Low Freq Trip | 47Hz± 0.3Hz for 50Hz, 57Hz± 0.3Hz for 60Hz | ||||||
Low Freq Re-engage | 48Hz± 0.3Hz for 50Hz, 58Hz± 0.3Hz for 60Hz | ||||||
High Freq Trip | 55Hz± 0.3Hz for 50Hz, 65Hz± 0.3Hz for 60Hz | ||||||
High Freq Re-engage | 54Hz± 0.3Hz for 50Hz, 64Hz± 0.3Hz for 60Hz | ||||||
Overload Protection | Circuit breaker | ||||||
Short Circuit Protection | Circuit breaker | ||||||
Transfer Switch Rating | 30amp | 40amp | |||||
Bypass Without Battery Connected | Yes | ||||||
Max. Bypass Current | 30amp | 40amp | |||||
Bypass Over Load Current | 35amp: alarm | 45amp: alarm | |||||
Solar Charger | Rated Voltage | 12V | 24V | ||||
Rated Charge Current | 40A | ||||||
Rated Output Current | 15A | ||||||
Self Consumption | < 10mA(at idle) | ||||||
Bulk Charge | 14.5V(default) | 29.0V(default) | |||||
Floating Charge① | 13.5V(default) | 27.0V(default) | |||||
Equalization Charge① | 14.0V(default) | 28.0V(default) | |||||
Over Charge Disconnection | 14.8V | 29.6V | |||||
Over Charge Recovery | 13.6V | 27.2V | |||||
Over Discharge Disconnection① | 10.8 V(default) | 21.6V(default) | |||||
Over Discharge Reconnection | 12.3V | 24.6V | |||||
TemperatureCompensation① | -13.2mV/℃ | -26.4mV/℃ | |||||
Ambient Temperature | 0-40℃(full load) 40-60℃(derating) | ||||||
Mechanical Specifications | |||||||
Mounting | Wall mount | ||||||
Inverter Dimensions(L*W*H) | 598*218*179mm | 470*190*340mm | |||||
Inverter Weight | 21KG | 23KG | 27KG | 38KG | 48KG | 48KG | |
Shipping Dimensions(L*W*H) | 740*315*300mm | 530*240*390mm | |||||
Shipping Weight | 23KG | 25KG | 29KG | 40KG | 50KG | 50KG | |
Display | Status LEDs / status LEDs+LCD | ||||||
Standard Warranty | 1 year |
APV Series Inverter&Solar Charger
Electrical Specvifications | ||||||||||||||||||
Model | APV1000W | APV1500W | APV2000W | APV3000W | APV4000W | APV5000W | APV6000W | |||||||||||
Output (Inverter mode) | Continuous Output Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | ||||||||||
Surge Rating | 3000W | 4500W | 6000W | 9000W | 12000W | 15000W | 18000W | |||||||||||
Output Waveform | Pure Sine wave/Same as input(Bypass mode) | |||||||||||||||||
Nominal Efficiency | >88%(Peak) | |||||||||||||||||
Line Mode Efficiency | >95% | |||||||||||||||||
Power Factor | 0.9-1.0 | |||||||||||||||||
Nominal OutputVoltage rms | 100-110-120Vac / 220-230-240Vac | |||||||||||||||||
Output Voltage Regulation | ±10% RMS | |||||||||||||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |||||||||||||||||
Short Circuit Protection | Yes( 1sec after fault ) | |||||||||||||||||
Typical Line Stansfer Time | 10ms(MAX) | |||||||||||||||||
THD | <10% | |||||||||||||||||
DC Input | Nominal Input Voltage | 12.0Vdc | ||||||||||||||||
( *2 for 24Vdc, *4 for 48Vdc) | ||||||||||||||||||
Minimum Start Voltage | 10.0Vdc | |||||||||||||||||
Low Battery Alarm | 10.5Vdc / 11.0Vdc | |||||||||||||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc | |||||||||||||||||
High Voltage Alarm | 16.0Vdc | |||||||||||||||||
Low Batteryvoltagerecover | 15.5Vdc | |||||||||||||||||
Idle Consumption-Search Mode | < 25 W when Power Saver On | |||||||||||||||||
AC Charger | Input Voltage Range | Wide: 90~135VAC / 164~243VAC;Narraw: 100~135VAC / 194~243VAC; | ||||||||||||||||
Output Voltage | Depends on battery type | |||||||||||||||||
Max Charge Rate | 35A / 70-90A Max (Charger Current Control) | |||||||||||||||||
Battery InitialVoltageforStart Up | Circuit breaker | |||||||||||||||||
Over ChargeProtectionShutdown | 15.7V for 12V( *2 for 24Vdc, *4 for 48Vdc) | |||||||||||||||||
Charger curve(4 stage constant current)4 step digital controlled progressive charge | Battery types ( *2 for 24Vdc, *4 for 48Vdc) | |||||||||||||||||
Battery type | Fast V Float V( *2 for 24Vdc, *4 for 48Vdc) | |||||||||||||||||
Gel U.S.A | 14.0 | 13.7 | ||||||||||||||||
A.G.M 1 | 14.1 | 13.4 | ||||||||||||||||
A.G.M 2 | 14.6 | 13.7 | ||||||||||||||||
Sealed Lead Acid | 14.4 | 13.6 | ||||||||||||||||
Gel Euro | 14.4 | 13.8 | ||||||||||||||||
Open Lead Acid | 14.8 | 13.3 | ||||||||||||||||
Calcium | 15.1 | 13.6 | ||||||||||||||||
De-sulphation | 15.5 for 4hrs | |||||||||||||||||
Remote Control | Yes. Optional | |||||||||||||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | ||||||||||||||||
Nominal Voltage | 120VAC / 230VAC | |||||||||||||||||
Low Voltage Trip | 90V±4%/184V/154V±4% | |||||||||||||||||
Low Voltage re engage | 100V±4%/194V/164V±4% | |||||||||||||||||
High Voltage Trip | 140V±4%/ 253V±4% | |||||||||||||||||
High Voltage re engage | 135V±4%/243V±4% | |||||||||||||||||
Max Input AC Voltage | 150VAC/270VAC | |||||||||||||||||
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | |||||||||||||||||
Low freq trip | 47Hz± 0.3Hz for 50Hz, 57Hz± 0.3Hz for 60Hz | |||||||||||||||||
Low freq re engage | 48Hz± 0.3Hz for 50Hz, 58Hz± 0.3Hz for 60Hz | |||||||||||||||||
High freq trip | 55Hz± 0.3Hz for 50Hz, 65Hz± 0.3Hz for 60Hz | |||||||||||||||||
High freq re engage | 54Hz± 0.3Hz for 50Hz, 64Hz± 0.3Hz for 60Hz | |||||||||||||||||
Overload protection | Circuit breaker | |||||||||||||||||
Short circuit protection | Circuit breaker | |||||||||||||||||
Transfer switch rating | 30amp | 40amp | ||||||||||||||||
Max bypass current | 30amp | 40amp | ||||||||||||||||
Bypass over load current | 35amp: Alarm | 45amp: Alarm | ||||||||||||||||
Solar Charger | Rated Voltage | 12V/24V/48V | ||||||||||||||||
Rated Charge Current | 40A/60A | |||||||||||||||||
Rated Output Current | 15A | |||||||||||||||||
Self Consumption | < 10mA | |||||||||||||||||
Bulk Charge | 14.5V(default) | ( *2 for 24Vdc, *4 for 48Vdc) | ||||||||||||||||
Floating Charge | 13.5V(default) | |||||||||||||||||
Equalization Charge | 14.0V(default) | |||||||||||||||||
Over ChargeDisconnection | 14.8V | |||||||||||||||||
Over Charge Recovery | 13.6V | |||||||||||||||||
Over DischargeDisconnection | 10.8 V(default) | |||||||||||||||||
Over DischargeReconnection | 12.3V | |||||||||||||||||
TemperatureCompensation | – 13.2mV/℃ | |||||||||||||||||
Ambient Temperature | 0-40℃(full load) 40-60℃(derating) | |||||||||||||||||
Mechanical Specifications | Mounting | Wall mount | ||||||||||||||||
Inverter Dimensions(L*W*H) | 598*218*179mm | 470*190*340mm | ||||||||||||||||
Inverter Weight | 21KG | 22kg | 23KG | 27KG | 38KG | 48KG | 48KG | |||||||||||
Shipping Dimensions(L*W*H) | 740*315*300mm | 530*240*390mm | ||||||||||||||||
Shipping Weight | 23KG | 24kg | 25KG | 29KG | 40KG | 50KG | 50KG | |||||||||||
Display | Status LEDs / Status LEDs+LCD | |||||||||||||||||
Standard Warranty | 1 Year |