APP Series Pure Sine Wave Inverter is a combination of an inverter, battery charger and AC auto-transfer switch into one complete system with a peak conversion efficiency of 92%.It is packed with unique features and it is one of the most advanced inverter/chargers in the market today. It features power factor corrected, sophisticated multi-stage charging and pure sine wave output with unprecedentedly high surge capability to meet demanding power needs of inductive loads without endangering the equipment.
Features of APP Pure Sine Wave Inverter, Charger
1. High overload ability up to 300% of rated power(20 sec)
2.Low quiescent current, low power “ Power Saving Mode ” to conserve energy
3. 4-step intelligent battery charging, PFC(Power Factor Correction) for charger
4. 8 pre set battery type selector plus de-sulphation for totally flat batteries
5. Powerful charge rate up to 110Amp, selectable from 0%-100%
6. 10 ms typical transfer time between battery and AC, guarantees power continuity
7.Smart remote control
8. 15s delay before transfer when AC resumes, extra protection for loads when used with generator
9. Allows start up and through power with depleted batteries10.30A/40A through current ability
11.Multiple controlled cooling fan
12. Extensive protections against various harsh situations
13. 13VDC battery recover point, dedicated for renewable energy systems
APP Series Inverter & Charger
Electrical Specifications | ||||||||
Model | APP 1000W | APP 1500W | APP 2000W | APP 3000W | APP 4000W | APP 5000W | APP 6000W | |
Inverter Output | Continuous Output Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W |
Surge Rating(20s) | 3000W | 4500W | 6000W | 9000W | 12000W | 15000W | 18000W | |
Capable of Starting Electric Motor | 1HP | 1.5HP | 2HP | 3HP | 4HP | 5HP | 6HP | |
Output Waveform | Pure Sine wave/Same as input(Bypass mode) | |||||||
Nominal Efficiency | >88%(Peak) | |||||||
Line Mode Efficiency | >95% | |||||||
Power Factor | 0.9-1.0 | |||||||
Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac | |||||||
Output Voltage Regulation | ±10% RMS | |||||||
Output Frequency | 50/60Hz ± 0.3Hz | |||||||
Short Circuit Protection | Yes, Current Limit Function (Fault after 1sec) | |||||||
Typical transfer Time | 10ms(Max) | |||||||
THD | < 10% | |||||||
DC Input | Nominal Input Voltage | 12.0Vdc | ||||||
( *2 for 24Vdc, *4 for 48Vdc) | ||||||||
Minimum Start Voltage | 10.0Vdc | |||||||
Low Battery Alarm | 10.5Vdc / 11.0Vdc | |||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc | |||||||
High Voltage Alarm & Fault | 16.0Vdc | |||||||
High DC Input Recovery | 15.5Vdc | |||||||
Low Battery voltage recover | 13.0Vdc | |||||||
Idle Consumption-Search Mode | < 25 W when Power Saver On | |||||||
Charge | Input Voltage Range | Wide: 90~135VAC / 164~243VAC;Narraw: 100~135VAC / 194~243VAC; | ||||||
Output Voltage | Depends on battery type | |||||||
Charger Breaker Rating | 10A | 10A | 10A | 20A | 20A | 30A | 30A | |
Max Charge Rate | 35A / 70-90A Max (Charger Current Control) | |||||||
Over Charge Protection Shutdown | 15.7V for 12Vdc ( *2 for 24Vdc, *4 for 48Vdc) | |||||||
Charger curve(4 stage constant current)4 step digital controlled progressive charge | Battery types ( *2 for 24Vdc, *4 for 48Vdc) | |||||||
Battery type | Fast Vdc | Float Vdc | ||||||
Gel U.S.A | 14.0 | 13.7 | ||||||
A.G.M 1 | 14.1 | 13.4 | ||||||
A.G.M 2 | 14.6 | 13.7 | ||||||
Sealed Lead Acid | 14.4 | 13.6 | ||||||
Gel Euro | 14.4 | 13.8 | ||||||
Open Lead Acid | 14.8 | 13.3 | ||||||
Calcium | 15.1 | 13.6 | ||||||
De-sulphation | 15.5 for 4hrs | |||||||
Remote Control | Yes. Optional | |||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | ||||||
Nominal Voltage | 120Vac | 230Vac | ||||||
Low Voltage Trip | 80V/90V±4% | 184V/154V±4% | ||||||
Low Voltage re engage | 90V/100V±4% | 194V/164V±4% | ||||||
High Voltage Trip | 140V±4% | 253V±4% | ||||||
High Voltage re engage | 135V±4% | 243V±4% | ||||||
Max Input AC Voltage | 150VAC | 270VAC | ||||||
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | |||||||
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | |||||||
Low Freq re engage | 48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz | |||||||
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | |||||||
High Freq re engage | 54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz | |||||||
Output Short circuit protection | Circuit breaker | |||||||
Bypass breaker rating | 10A | 15A | 20A | 30A | 30A | 40A | 40A | |
Transfer switch rating | 30amp for UL & TUV | 40amp for UL | ||||||
Max bypass current | 30amp | 40amp | ||||||
Mechanical Specification | Mounting | Wall mount | ||||||
Inverter Dimensions(L*W*H) | 382*218*179mm | 442*218*179mm | 598*218*179mm | |||||
Inverter Weight | 16KG | 17KG | 20KG | 24KG | 35KG | 45KG | 45KG | |
Shipping Dimensions(L*W*H) | 520*315*300mm | 580*315*300mm | 740*315*300mm | |||||
Shipping Weight | 18KG | 19KG | 22KG | 26KG | 37KG | 47KG | 47KG | |
Display | Status LEDs / Status LEDs+LCD | |||||||
Standard Warranty | 1 Year |