TPP Series Inverter & Charger |
Electrical Specifications |
| Model | TPP 3KW | TPP 4.5KW | TPP 6KW | TPP 9KW | TPP 12KW | TPP 15KW | TPP 18KW | TPP 24KW | TPP 30KW | TPP 36KW | TPP 45KW |
Inverter Output | Continuous Output Power | 3000W | 4500W | 6000W | 9000W | 12000W | 15000W | 18000W | 24000W | 30000W | 36000W | 45000W |
Surge Rating(20s) | 9000W | 13500W | 18000W | 27000W | 36000W | 45000W | 54000W | 72000W | 90000W | 108000W | 135000W |
Capable of Starting Electric Motor | 3HP | 4.5HP | 6HP | 9HP | 12HP | 15HP | 18HP | 24HP | 30HP | 36HP | 45HP |
Unbalance Load Acceptable | 100% |
DC Input Voltage | 12.0/24.0/48.0Vdc | 24.0/48.0Vdc | 48Vdc |
Output Waveform | Pure Sine wave/Same as input(Bypass mode) |
Nominal Efficiency | 89%(Peak) |
Line Mode Efficiency | >95% |
Power Factor | 0.9-1.0 |
Connection mode | 3-phase 4-wire system+Gnd |
Output voltage rating | 3AC/N 400V/207V |
Output phase voltage | 120/ 230VAC | 230VAC |
Output Voltage Regulation | ±10% RMS |
Output Frequency | 50/60Hz ± 0.3Hz |
Short Circuit Protection | Yes, Current Limit Function (Fault after 60ms) |
Typical transfer Time | Typical 6-8ms,10ms(Max) |
THD | < 3%(Linear Load) |
DC Input | Nominal Input Voltage | 12.0/24.0/48.0Vdc | 24.0/48.0Vdc | 48Vdc |
Minimum Start Voltage | 10.5Vdc / 11.0Vdc ( *2 for 24Vdc, *4 for 48Vdc) |
Low Battery Alarm | 10.5Vdc / 11.0Vdc ( *2 for 24Vdc, *4 for 48Vdc) |
Low Battery Trip | 10.0Vdc / 10.5Vdc ( *2 for 24Vdc, *4 for 48Vdc) |
High Voltage Alarm & Fault | 16.0Vdc ( *2 for 24Vdc, *4 for 48Vdc) |
High DC Input Recovery | 15.5Vdc ( *2 for 24Vdc, *4 for 48Vdc) |
Low Battery Voltage Recover | 13.0Vdc ( *2 for 24Vdc, *4 for 48Vdc) |
Idle Consumption-Search Mode | < 100 W when Power Saver On |
Charge | Input Voltage Range | Narrow: 96~132VAC / 184~253VAC;Wide: 70~135VAC / 140-270VAC; |
Input Frequency Range | Narrow: 47-55±0.3Hz for 50Hz, 57-65±0.3Hz for 60HzWide:40-70±0.3Hz for 50Hz/60Hz |
Output Voltage | Same as input |
Charger Breaker Rating(230Vac) | 10A | 10A | 10A | 20A | 20A | 30A | 30A | 40A | 50A | 60A | 80A |
Charger Breaker Rating(120Vac) | 10A | 20A | 20A | 30A | 40A | 50A | 60A | | | | |
Max Charge Rate | 40A*3 | 60A*3 | 80A*3 | 120A*3 | 160A*3 | 100A*3 | 120A*3 | 80A*3 | 100A*3 | 120A*3 | 150A*3 |
1/2 for 24Vdc, 1/4 for 48Vdc | 1/2 for 48Vdc | 48Vdc |
Power Factor | 0.97 MAX |
Over Charge Protection Shutdown | 15.7V for 12Vdc ( *2 for 24Vdc, *4 for 48Vdc) |
Battery type | Fast Vdc | Float Vdc |
Gel U.S.A | 14.0 | 13.7 |
A.G.M 1 | 14.1 | 13.4 |
A.G.M 2 | 14.6 | 13.7 |
Sealed Lead Acid | 14.4 | 13.6 |
Gel Euro | 14.4 | 13.8 |
Open Lead Acid | 14.8 | 13.3 |
Calcium | 15.1 | 13.6 |
De-sulphation | 15.5 for 4hrs |
Remote Control | Yes. Optional(LED/LCD) |
Bypass &Protection | Input Voltage Waveform | Sine wave (Grid or Generator) |
Nominal Voltage | 120Vac | 230Vac |
Low Voltage Trip | 70V/96V±4% | 184V/154V±4% |
Low Voltage re engage | 75V/100V±4% | 194V/164V±4% |
High Voltage Trip | 130V±4% | 253V/260V±4% |
High Voltage re engage | 135V±4% | 243V/270V±4% |
Max Input AC Voltage | 150VAC | 300VAC |
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) |
Low Freq Trip | Narrow: 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz Wide:40±0.3Hz for 50Hz/60Hz |
Low Freq re engage | Narrow: 48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz Wide:42±0.3Hz for 50Hz/60Hz |
High Freq Trip | Narrow: 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz Wide:70±0.3Hz for 50Hz/60Hz |
High Freq re engage | Narrow: 54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz Wide:68±0.3Hz for 50Hz/60Hz |
Output Short circuit protection | Circuit breaker |
Bypass breaker rating(230Vac) | 10A | 10A | 10A | 20A | 20A | 30A | 30A | 40A | 50A | 60A | 80A |
Bypass breaker rating(120Vac) | 10A | 20A | 20A | 30A | 40A | 50A | 60A | | | | |
Other | Communication methods | RS232/458/CAN |
Display | LED+LCD |